Host PLC
Gateway Unit etc.
Double Shield Cable
Recommend : TAIYO ELECTRIC WIRE & CABLE
HK-SB/20276×L
2P×AWG22
e-Con connector
(Made of AMP 4-1473562-4 : Green)
SIO Isolator
e-Con connector
Pressure-weld
Vinyl cable
(AWG22)
Weld
Shield cable
Cable tube
Double shield cable
Locking claw
Pin No. of e-Con Connector
Wire Connection Port
Locking claw
(3) Pressure Welding Method for the e-Con Connector for the Client-made Cable
(RS485 Communication Line)
For the connection to the e-Con connector, use the cable with the same core-wire size (equivalent to
AWG22) without peeling off the jacket of that core wires. If the jacket is peeled off, short-circuit might
be caused due to a connection error.
IAI America Inc.
Head Office: 2690W 237th Street Torrance, CA 90505
TEL (310) 891-6015 FAX (310) 891-0815
Chicago Office: 1261 Hamilton Parkway Itasca, IL 60143
TEL (630) 467-9900 FAX (630) 467-9912
Atlanta Office: 1220-E Kennestone Circle,Marrietta,GA 30066
TEL (678) 354-9470 FAX (678) 354-9471
website: www.intelligentactuator.com
IAI Industrieroboter GmbH
Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany
TEL 06196-88950 FAX 06196-889524
Use the following procedure for the connection to the
attached e-Con connector.
Peel off the jacket 15 to 20 mm from the
double shield cable.
Twist the shield wires and weld them onto the
vinyl cable equivalent to AWG22.
Cover it with the cable protection tube
(perform the terminal treatment using the
shrink tube).
Without peeling off the core jacket, insert four
core wires into the connector cable insertion
holes (SDA, SDB, GND, FG).
Keeping the core wires in the holes,
pressure-weld the cable press-fitting housing
from above.
Manual No.: ME0207-1A
CAUTION