Iai-america ISPDACR-ESD Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Iai-america ISPDACR-ESD. IAI America ISPDACR-ESD User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 126
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
IS Series Actuator
Operating Manual
Dust-proof Type
ISD
ISDA ISPDA
Cleanroom Type
ISDCR
ISPDCR ISDACR ISPDACR
Cleanroom Type, Antistatic Specification
ISDACR-ESD
Seventh Edition
Vista de pagina 0
1 2 3 4 5 6 ... 125 126

Indice de contenidos

Pagina 1 - Operating Manual

IS Series ActuatorOperating ManualDust-proof TypeISDISDA ISPDACleanroom TypeISDCRISPDCR ISDACR ISPDACRCleanroom Type, Antistatic SpecificationISDACR-E

Pagina 2

2No.Operation Description Description 2 Transportation Ɣ When carrying a heavy object, do the work with two or more persons or utilize equipment such

Pagina 3 - [Important]

9213. Appendix13.1.3 ISDA-M-200, ISPDA-M-200 4-M6, depth 18 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm) Cable joint connector *1 HomeA

Pagina 4 - CE Marking

9313. Appendix13.1.4 ISDA-MX-200, ISPDA-MX-200 4-M6, depth 18 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm) Cable joint connector *1 Hom

Pagina 5 - Table of Contents

9413. Appendix13.1.5 ISDA-L-200, ISPDA-L-200 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm) Cable joint connector *1 HomeAAt least 100 or

Pagina 6

9513. Appendix13.1.6 ISDA-L-400, ISPDA-L-400 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm) Cable joint connector *1 HomeAAt least 100 or

Pagina 7

9613. Appendix13.1.7 ISDA-LX-200, ISPDA-LX-200 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm) Cable joint connector *1 HomeAAt least 100

Pagina 8

9713. Appendix13.1.8 ISDA-LX-400, ISPDA-LX-400 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm) Cable joint connector *1 HomeAAt least 100

Pagina 9 - Safety Guide

9813. Appendix13.1.9 ISDACR-S, ISPDACR-S 2-6H7, depth 10 (tolerance for reamed hole pitch r0.02 mm) Cable joint connector *1 HomeAAt least 100 or m

Pagina 10

9913. Appendix13.1.10 ISDACR-M-100, ISPDACR-M-100 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm)Cable joint connector *1 HomeAAt least

Pagina 11

10013. Appendix13.1.11 ISDACR-M-200, ISPDACR-M-200 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm)Cable joint connector *1 HomeAAt least

Pagina 12

10113. Appendix13.1.12 ISDACR-MX-200, ISPDACR-MX-200 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm)Cable joint connector *1 HomeAAt least

Pagina 13

3No.Operation Description Description (2) Cable Wiring Ɣ 8VHRXUFRPSDQ\¶VJHQXLQHFDEOHVIRUFRQQHFWLQJEHWZHHQWKHDFWXDWRUDQGFRQWUROOHUDQGIRU

Pagina 14

10213. Appendix13.1.13 ISDACR-L, ISPDACR-L-200 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm)Cable joint connector *1 HomeAAt least 100

Pagina 15 - Alert Indication

10313. Appendix13.1.14 ISDACR-L-400, ISPDACR-L-400 with brake (option) Weight (kg) 4-8H7, depth 102-8H7, depth 10 (tolerance for reamed hole pitch

Pagina 16

10413. Appendix13.1.15 ISDACR-LX-200, ISPDACR-LX-200 Cable joint connector *1 At least 100 or more with brake (optional) 4-8H7, depth 102-8H7, depth

Pagina 17 - [How to Calculate Duty]

10513. Appendix13.1.16 ISDACR-LX-400, ISPDACR-LX-400 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm)Cable joint connector *1 HomeAAt lea

Pagina 18 - 8. Stainless Sheet

10613. Appendix13.1.17 ISDACR-W-600, ISPDACR-W-600 Cable joint connector *1 HomeAt least 100 or more Stroke Weight (kg) 4-M8, depth 24 m-M8, depth 25

Pagina 19 - Names of the Parts

10713. Appendix13.1.18 ISDACR-W-750, ISPDACR-W-750 Cable joint connector *1 HomeAt least 100 or more Stroke Weight (kg) 4-M8, depth 24 m-M8, depth 25

Pagina 20

10813. Appendix13.1.19 ISDACR-WX-600, ISPDACR-WX-600 Cable joint connector *1 HomeAt least 100 or more Stroke Weight (kg) 4-M8, depth 24 m-M8, depth 2

Pagina 21

10913. Appendix13.1.20 ISDACR-WX-750, ISPDACR-WX-750 Cable joint connector *1 HomeAt least 100 or more Stroke Weight (kg) 4-M8, depth 24 m-M8, depth 2

Pagina 22 - 1.2.1 XSEL-J/K controllers

11013. Appendix13.1.21 ISDACR-ESD S (Small) Type (60 W) 2-6H7, depth 10 (tolerance for reamed hole pitch r0.02 mm) At least 100 or more Stroke Wei

Pagina 23 - 1.2.3 SSEL controllers

11113. Appendix13.1.22 ISDACR-ESD M (Medium) Type (100 W/200 W) 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm)At least 100 or more Str

Pagina 24 - 1.2.4 SCON controllers

4No.Operation Description Description 4 Installation and Start (4) Safety Measures Ɣ When the work is carried out with 2 or more persons, make it cle

Pagina 25 - 1.4 How to Read the Model

11213. Appendix13.1.23 ISDACR-ESD L (Large) Type (200 W/400 W) 2-8H7, depth 10 (tolerance for reamed hole pitch r0.02 mm)At least 100 or more Stro

Pagina 26 - Robot cable

11314. Warranty14. Warranty14.1 Warranty PeriodOne of the following periods, whichever is shorter:18 months after shipment from IAI12 months after del

Pagina 27 - Antistatic specification

11414. Warranty and Applications14.5 Conditions of Conformance with Applicable Standards/Regulations, Etc.,(1) If our product is combined

Pagina 28 - 2. Specification

11515. Change History15. Change HistorynoisiveRfonoitpircseDetaDnoisiveRFirst editionSecond editionP. 9 Handling PrecautionsChanged “ …duty of 50%” to

Pagina 31 - *1 Default

Manual No.: ME3682-7A (January 2013)The information contained in this document is subject to change without notice for purposes ofproduct improvement.

Pagina 32

5No.Operation Description Description 6 Trial Operation Ɣ When the work is carried out with 2 or more persons, make it clear who is to be the leader

Pagina 33 - Ma Mb Mc

6No.Operation Description Description 8 Maintenance and InspectionƔ When the work is carried out with 2 or more persons, make it clear who is to be t

Pagina 34

7Alert Indication 7KHVDIHW\SUHFDXWLRQVDUHGLYLGHGLQWR³'DQJHU´³:DUQLQJ´³&DXWLRQ´DQG³1RWLFH´DFFRUGLQJWRWKHZDUQLQJOHYHODVIROO

Pagina 35 - 3. Life

8Handling Precautions1. Do not set speeds and accelerations/decelerations equal to or greaterthan the respective ratings.Do not set speeds and acceler

Pagina 36 - 4.1 Installation Environment

96. Use your actuator at duties not exceeding the calculated reference duty.“Duty” indicates the utilization rate of an actuator (time during which th

Pagina 37 - 5. Installation

107. Transport7.1 Handling a Single AxisTake note of the following points when transporting each actuator alone.7.1.1 Handling the Packed UnitUnless o

Pagina 38 - Tap size

11Names of the Parts In this operating manual, the left and right sides are indicated by looking at the actuator from the motor end, with the actuator

Pagina 40 - 5.3 Installing the Slider

122. Cleanroom Types ISDCR/ISPDCR/ISDACR/ISPDACR[Refer to 13.1, “External Dimensions” for details on the reference surface.] For details on the refer

Pagina 41

133. Cleanroom Types ISPDCR-W/ISDACR-W/ISPDACR-W [Refer to 13.1, “External Dimensions” for details on the reference surface.] For details on the refe

Pagina 42 - 5.4 Mounting Surface

141. Checking the Product1. Checking the ProductIf based on a standard configuration, this product consists of the items listed below.Caution: Check t

Pagina 43 - 5.5 Using T-slots

151. Checking the Product1.2.2 XSEL-P/Q controllers No. Name Control No. 1 Operation Manual for XSEL-P/Q Controller MJ01482 Operation Manual for XS

Pagina 44

161. Checking the Product1.2.4 SCON controllers No. Name Control No. 1 Operation Manual for SCON Controller MJ0161 2 Operation Manual for PC Softwa

Pagina 45 - 6.1 Wiring

171. Checking the Product1.4 How to Read the Model1.4.1 Standard type ISDA/ISPDA series<Series>Standard accuracyISD, ISDAHigh accuracyISPDA<O

Pagina 46 - 6. Connecting the Controller

181. Checking the Product1.4.2 Cleanroom Type ISDACR/ISPDACR<Series>Standard accuracyISDCR, ISDACR High accuracyISPDCR, ISPDACR<Options>AQ

Pagina 47 - Signal lines (flat cable)

191. Checking the Product1.4.3 Cleanroom Type, Antistatic Specification ISDACR-EDS<Series>Standard accuracyISDACR<Encoder type>A: Absolute

Pagina 48 - Intermediate support

206SHFL¿FDWLRQ2. Specification (1) Maximum speed The maximum speed of the actuator is limited to prevent resonance of the ball screw shaft and also

Pagina 49 - 7. Setting the Home Position

216SHFL¿FDWLRQ(2) Acceleration and loading capacity Loading capacity by acceleration (kg) Type Motor output (W) Lead (mm) Maximum Speed (mm/sec) R

Pagina 50 - Sticker details

Please Read Before UseThank you for purchasing our product.This Operation Manual explains the handling methods, structure and maintenance of this prod

Pagina 51 - 8. Options

226SHFL¿FDWLRQ(3) Rated thrust Type Motor type (W) Lead (mm) Rated thrust (N)4 254.8 8 127.4 S 60 16 63.7 5 340.1 10 169.5 10020 84.3 10 340.1 M

Pagina 52 - 8.2 Brake

236SHFL¿FDWLRQ(4) Driving method Driving method Type Motor type (W) Lead (mm)Encoderpulses*1ISD, ISDA, ISDCR, ISDACR ISPDA, ISPDCR,ISPDACR48S 60 1

Pagina 53

246SHFL¿FDWLRQ(6) Loads applied to the actuator [Standard types ISD/ISDA/ISPDA and cleanroom types ISDCR/ISPDCR/ISDACR/ISPDACR (excluding ISPDCR-W

Pagina 54 - 9. Motor/Encoder Cables

256SHFL¿FDWLRQ[Cleanroom types ISPDCR-W/ISDACR-W/ISPDACR-W]Allowable load moments and allowable overhung load lengths of each actuator are shown be

Pagina 55

266SHFL¿FDWLRQCaution: Make sure the load installed on the actuator is not longer than the allowable overhung load length (L). If the load is long

Pagina 56 - Example) 080 = 8 m

273. Life3. Life The “rated load” is one factor that relates to the traveling life. There are two types of “rated load,” namely “static rated load” an

Pagina 57

284. Installation and Storage/Preservation Environment4. Installation and Storage/Preservation Environment 4.1 Installation Environment The actuator

Pagina 58 - 10. Maintenance/Inspection

295. Installation5. Installation This chapter explains how to install your actuator on a mechanical system. 5.1 Installation Install the actuator as e

Pagina 59 - 10.3 External Cleaning

305. Installation5.2 Installing the Actuator Tapped mounting holes are provided on the back of the actuator base. Use these tapped holes to install t

Pagina 60 - 10.5 Interior Check

315. InstallationTightening torqueApplicable boltBolt seating surface is steel Bolt seating surface is aluminumM8 31.3 N-m (3.19 kgf-m) 14 N-m (1.43 k

Pagina 61 - 10.7.1 ISD/ISDA/ISPDA

CE MarkingIf a compliance with the CE Marking is required, please follow Overseas Standards Compliance Manual (ME0287) that is provided separately.[Ap

Pagina 62

325. Installation5.3 Installing the Slider x The slider has tapped holes, so affix the load using these holes. Affix the transferring load in the sa

Pagina 63 - Motor end

335. InstallationTightening torqueApplicable boltBolt seating surface is steel Bolt seating surface is aluminumM6 12.3 N-m (1.26 kgf-m) 5.4 N-m (0.55

Pagina 64

345. Installation5.4 Mounting Surface x The mounting frame should have sufficient rigidity to avoid generation of vibration. x The surface where the

Pagina 65 - Front side

355. Installation5.5 Using T-slots M4 T-slots are provided on the side face of the base for installing the connector box or other item that must be c

Pagina 66

365. Installation5.6 Suction for the Cleanroom Type IS actuators of cleanroom specification with protective stainless sheet can demonstrate their des

Pagina 67

376. Connecting the Controller6. Connecting the Controller The controller wiring is explained using a single-axis actuator. 6.1 Wiring The actuator a

Pagina 68

386. Connecting the ControllerWhen designing an application system using IAI actuators and controllers, incorrect wiring or connection of each cable m

Pagina 69

396. Connecting the ControllerCautions for use of a cable trackThe supplied cable is not a robot cable,so never store it in a cable track.Do not lay s

Pagina 70

407. Setting the Home Position7. Setting the Home Position 7.1 Home Return The home return procedure for this actuator is explained below. Home retur

Pagina 71

417. Setting the Home Position7.3 Changing the Home Direction If the home direction is changed after the actuator has been delivered, the home direct

Pagina 72

Table of ContentsSafety Guide...Handli

Pagina 73

427. Setting the Home Position7.4 How to Use the Homing Mark Stickers  Attach these stickers to the product, as necessary, to indicate the home dire

Pagina 74

438. OptionsWith AQ seal No lubrication With AQ seal No lubrication Stopped after 1,800 km due to large wearNo problem was found after 15,000 kmStoppe

Pagina 75 - Motor bracket

448. Options8.2 Brake The brake is a mechanism to retain the slider of a vertically installed actuator so that the slider will not drop when the power

Pagina 76 - Front cover

458. Options8.4 Guide with Ball Retention Mechanism (Structure) A spacer (retainer) is inserted between adjacent balls (steel balls) in the guide to

Pagina 77

469. Motor/Encoder Cables9. Motor/Encoder Cables 9.1 Standard The same cables are used regardless of the actuator model. The applicable cables vary de

Pagina 78

479. Motor/Encoder Cables[3] Limit switch cable CB-X-LC*** [4] Encoder cable CB-X1-PA*** [5] Encoder cable with LS CB-X2-PLA*** (Front vies) Control

Pagina 79

489. Motor/Encoder Cables9.2 CE Specification (Option Indicated by “EU” in Model Number) The same cables are used regardless of the actuator model. T

Pagina 80

499. Motor/Encoder Cables[3] Encoder cable with LS CB-XEU1-PLA*** * *** indicates the cable length (L). Up to 30 m can be specified. Example) 080 =

Pagina 81

5010. Maintenance/Inspection10. Maintenance/Inspection 10.1 Inspection Items and Intervals Perform maintenance/inspection according to the following

Pagina 82

5110. Maintenance/Inspection10.3 External Cleaning x Clean the exterior surfaces from time to time. x Wipe off dirt with a soft cloth. x Depending

Pagina 83

7. Setting the Home Position...7.1 Home Return ...

Pagina 84

5210. Maintenance/Inspection10.5 Interior Check Turn off the power, remove the stainless sheet and visually inspect the interior. For the interior ins

Pagina 85

5310. Maintenance/Inspection10.6 Cleaning the interior x Wipe off dirt with a soft cloth. x If constituents of grease have separated and base oil h

Pagina 86

5410. Maintenance/InspectionGrease Supply MethodGrease nipples are provided on the end face of the slider, so add grease from these nipples. To add gr

Pagina 87

5510. Maintenance/Inspection10.7.2 ISDCR/ISPDCR/ISDACR/ISPDACRApplicable GreaseOur guides use urea grease that offers excellent low-dust-raising prope

Pagina 88

5610. Maintenance/InspectionMotor endGuide (right)Guide (left)Guide (right)Guide (left)Guide (right)Guide (left)Guide (left)Guide (right)Motor endMoto

Pagina 89 - . How to

5710. Maintenance/Inspection10.7.3 ISPDCR-W/ISDACR-W/ISPDACR-WApplicable GreaseLow-dust-raising urea grease is used.The following blends of grease are

Pagina 90

5811. Replacement/Adjustment Procedure for Stainless Sheet11. Replacement/Adjustment Procedure for Stainless Sheet “What you need for replacement” x

Pagina 91

5911. Replacement/Adjustment Procedure for Stainless Sheet“Procedure” (1) Remove the screws affixing the slider cover. After removing the slider cove

Pagina 92 - Select Yes

6011. Replacement/Adjustment Procedure for Stainless Sheet(2) Remove the motor cover. (3) Remove the screws retainer the current stainless sheet and

Pagina 93

6111. Replacement/Adjustment Procedure for Stainless Sheet(7) Adjust the tension of the stainless sheet. [1] While looking in through the center ope

Pagina 94 - * The setting unit is mm

13.1.4 ISDA-MX-200, ISPDA-MX-200 ...13.1.5 ISDA-L-200, ISPDA-L-200 ...

Pagina 95 - Click OK

6211. Replacement/Adjustment Procedure for Stainless Sheet[3] Move the slider and check the tension of the stainless sheet over the entire stroke. If

Pagina 96 - 12.3.3 P-Driver Controllers

6312. Motor Replacement Procedures12. Motor Replacement Procedures (Note) Motors in the ISD, ISDCR and ISPDCR series cannot be replaced by customers

Pagina 97 - (5) Write the new data

6412. Motor Replacement Procedures(2) Removing the rear cover Remove the four bolts affixing the rear cover. <List of rear cover affixing bolts>

Pagina 98

6512. Motor Replacement Procedures(4) Removing the coupling (on the ball screw side) Loosen the bolts affixing the coupling. <List of coupling aff

Pagina 99

6612. Motor Replacement Procedures(7) Wiring the new motor unit x Connect to the motor unit the motor cable and encoder cable attached to the motor

Pagina 100 - SE: Stroke end

6712. Motor Replacement Procedures(8) Positioning the slider Adjust the affixed position of the slider so that the motor can be installed. Use a scal

Pagina 101

6812. Motor Replacement Proceduresx Reversed-home specification (9) Positioning the motor x Turn on the controller power and use the PC software or

Pagina 102

6912. Motor Replacement Procedures(10) Installing the new motor unit x With the servo turned on, insert the coupling of the motor unit into the openi

Pagina 103

7012. Motor Replacement Procedures(11) Tightening the coupling x Loosely tighten the coupling bolt using an Allen wrench, and then turn off the serv

Pagina 104

7112. Motor Replacement Procedures(12) Installing the rear cover x Affix the ground wire using the cap screw. <List of ground wires, affixing bolt

Pagina 106

7212. Motor Replacement Procedures(13) Installing the motor cover Affix the motor cover using two bolts. <List of motor cover affixing bolts and ti

Pagina 107

7312. Motor Replacement Procedures12.2 Replacing the Motor of the ISDACR/ISPDACR Series “What you need for replacement” x New motor (with a coupling

Pagina 108

7412. Motor Replacement Procedures(3) Remove the rear cover. Use an Allen wrench of 4 mm across flats to remove the two hexagonal socket head bolts.

Pagina 109 - 13. Appendix

7512. Motor Replacement Proceduresx Standard home specification (home on the motor side) Type Distance between the inner end face of the motor bracke

Pagina 110

7612. Motor Replacement Procedures(5) Loosen the coupling (ball screw side). Use an Allen wrench of 4 mm across flats to loosen the hexagonal socket

Pagina 111

7712. Motor Replacement Procedures(8) Plug the motor connector and encoder connector on the extension cables into the new motor. (9) Adjust the moto

Pagina 112

7812. Motor Replacement Procedures(10) Install the new motor. With the servo turned on, press the motor coupling into the end of the ball screw shaft

Pagina 113

7912. Motor Replacement Procedures(14) Install the rear cover. Store the connectors in the space below the motor, and use an Allen wrench of 4 mm acro

Pagina 114

8012. Motor Replacement Procedures(17) Correcting the position deviation [1] Turn on the controller power. Next, use a PC software or teaching pendan

Pagina 115

8112. Motor Replacement Procedures12.3 How to Set the Home Preset and Home Return Offset Correct the position deviation by changing the parameter for

Pagina 116 - L (stroke + 665)

1Safety Guide³6DIHW\*XLGH´KDVEHHQZULWWHQWRXVHWKHPDFKLQHVDIHO\DQGVRSUHYHQWSHUVRQDOLQMXU\RUSURSHUW\GDPDJHEHIRUHKDQG0DNHVXUHWRUHDG

Pagina 117

8212. Motor Replacement Procedures(3) Open the parameter screen. (4) Select the axis-specific parameter tab. (5) In the axis-specific parameter tab

Pagina 118

8312. Motor Replacement Procedures(7) Write the new data. (8) Transfer the data to the controller. (9) Click OK.(10) Write the data to the flash ROM

Pagina 119

8412. Motor Replacement Procedures(11) Restart the controller. Select Yes.

Pagina 120

8512. Motor Replacement Procedures12.3.2 ECON and SCON Controllers (1) Open the position edit screen. On the PC software screen, click , sele

Pagina 121 - 14.4 Limited Liability

8612. Motor Replacement Procedures(3) Open the parameter screen. (4) The user parameter screen appears. (5) Change user parameter No. 13 (Home Retu

Pagina 122 - and Applications

8712. Motor Replacement Procedures(6) Write the new data. Click the controller transfer button, and then click OK.* After the data has been written,

Pagina 123 - 15. Change History

8812. Motor Replacement Procedures12.3.3 P-Driver Controllers (1) Open the jog screen. Click the jog button on the PC software screen. Next,

Pagina 124

8912. Motor Replacement Procedures(3) Open the parameter edit screen. Click this button to open the parameter screen. (4) Change the setting of No.

Pagina 125

9013. Appendix13. Appendix Caution: For the external dimensions of ISD/ISDCR/ISPDCR actuators, refer to the catalogs of old products. You can downloa

Pagina 126 - 13.01.000

9113. Appendix13.1.2 ISDA-M-100, ISPDA-M-100  Dimension, Mass and Maximum Speed by Stroke4-M6, depth 18 2-8H7, depth 10 (tolerance for reamed hole p

Comentarios a estos manuales

Sin comentarios