140
10. Common Items and Others
9.4 Useful functions for X-SEL controller adjustment
(1) When a standard or expansion I/O board is installed onto the K-type controller, X-SEL can individually be
started up without connection of the 24V DC power for I/O.
(2) When a CC-Link board is installed, X-SEL can individually be started up without establishment of the network.
In either case, set the relevant I/O parameters of No. 10 to No. 13 to “0: Non-monitoring.”
(Note) After completing the required operation or adjustment, be sure to restore the parameters. Without doing so, an error
check of the relevant slots of the boards will not be carried out.