3. X-SEL-J/K/P/Q/JX/KX/PX/QX
X-SEL J/K type controller I/O parameter
No. Parameter name
Default
(reference)
Input
range
Setting Remarks
1 I/O port assignment type 1 0 – 20 1 0: Fixed assignment
1: Automatic assignment (Priority: slot 1 )
* The ports only in the continuous
installation range from slot 1 are
assigned for safety.)
2 Standard I/O fixed assignment
time:
Input port start No. (I/O 1)
000 -1 – 599 000 0 + (multiples of 8) (Invalid for negative values)
3 Standard I/O fixed assignment
time:
Output port start No. (I/O 1)
300 -1 – 599 300 300 + (multiples of 8)
(Invalid for negative values)
4 Expansion I/O 1 fixed assignment
time: Input port start No. (I/O 2)
-1 -1 – 599 -1 0 + (multiples of 8) (Invalid for negative values)
(Slot next to the standard I/O)
5 Expansion I/O 1 fixed assignment
time: Output port start No. (I/O 2)
-1 -1 – 599 -1 300 + (multiples of 8)
(Invalid for negative values)
6 Expansion I/O 2 fixed assignment
time: Input port start No. (I/O 3)
-1 -1 – 599 -1 0 + (multiples of 8) (Invalid for negative values)
7 Expansion I/O 2 fixed assignment
time: Output port start No. (I/O 3)
-1 -1 – 599 -1 300 + (multiples of 8)
(Invalid for negative values)
8 Expansion I/O 3 fixed assignment
time: Input port start No. (I/O 4)
-1 -1 – 599 -1 0 + (multiples of 8) (Invalid for negative values)
9 Expansion I/O 3 fixed assignment
time: Output port start No. (I/O 4)
-1 -1 – 599 -1 300 + (multiples of 8)
(Invalid for negative values)
10 Standard I/O error monitoring
(I/O 1)
2 0 – 5 2
11 Expansion I/O 1 error monitoring
(I/O 2)
1 0 – 5 1
12 Expansion I/O 2 error monitoring
(I/O 3)
0 0 – 5 0
13 Expansion I/O 3 error monitoring
(I/O 4)
0 0 – 5 0
0: Non-monitoring
1: Monitoring
2: Monitoring (Non-monitoring of 24V I/O
power related errors)
(Main application of Ver. 0.55 or later)
3: Monitoring (Monitoring of 24V I/O power
related errors only)
14 Network I/F card remote:
Number of ports used for input
64 0 – 256 256 Multiples of 16
15 Network I/F card remote:
Number of ports used for output
64 0 – 256 256 Multiples of 16
(I/O 1) to (I/O 4) indicate the slot numbers.