3. X-SEL-J/K/P/Q/JX/KX/PX/QX
(3) Transmission and receipt of signals in remote register areas
The I/O parameter No. 120 allows the data in one word (16 bits) to be transmitted by reversing the order of
the higher-order byte (higher-order 8 bits) and the lower-order byte (lower-order 8 bits).
(a) When the I/O parameter No. 120 is set to “1”
: On, : OFF
X-SEL port No. (Input) 079 078 077 076 075 074 073 072 071 070 069 068 067 066 065 064
ON/OFF 䖃䖃䖃䖃䕿䕿䕿䕿
Hexadecimal data F 0 8 1
PLC: RWwn (Output) F E D C B A 9 8 7 6 5 4 3 2 1 0
ON/OFF 䖃䖃䖃䖃䕿䕿䕿䕿
Hexadecimal data F 0 8 1
X-SEL port No. (Output) 379 378 377 376 375 374 373 372 371 370 369 368 367 366 365 364
ON/OFF 䖃䖃䖃䖃䕿䕿䕿䕿
Hexadecimal data F 0 8 1
PLC: RWrn (Input) F E D C B A 9 8 7 6 5 4 3 2 1 0
ON/OFF 䖃䖃䖃䖃䕿䕿䕿䕿
Hexadecimal data F 0 8 1