Iai-america PCON-CFA Manual de usuario Pagina 192

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 294
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 191
4. SCON-CA
184
PLC output
Address (* “n” indicates the node address of each axis.)
When the target position is shown using the negative figure, it is expressed using the complement of 2.
1 word = 2 b
y
tes =16 bits
Target
position
(lower word)
Target
position
(upper word)
n+2, n+3
n+0, n+1
Positioning
band
(lower word)
Positioning
band
(upper word)
Speed
Acceleration/
deceleration
Pressing
current-limiting
value
Control signal
n+14, n+15
n+12, n+13
n+10, n+11
n+8, n+9
n+6, n+7
n+4, n+5
Vista de pagina 191
1 2 ... 187 188 189 190 191 192 193 194 195 196 197 ... 293 294

Comentarios a estos manuales

Sin comentarios