56
/
3. Operation
3.2.2 Power Input
1) Releasetheemergencystopstatusorenablethemotordrivingpowersupply.
2) Supply24VDCfortheI/O.
3) Supply24VDCforthecontroller.
4) InputtheServo-motorONsignalfromthePLCside
(*3)
.
,QSXWWKH%DFNZDUG3RVLWLRQPRYHPHQWFRPPDQGDQGVLJQDOVDW¿UVWIURPWKH3/&VLGH
[Refer to 3.2.3 Home-return]
Note 1
:KHQWKHKRPHUHWXUQRSHUDWLRQLVVHWWR³0$18´LQWKHLQLWLDOVHWWLQJDQGWKH¿UVW67LVWXUQHG21WKH
actuatorisreturnedtothehomepositionandtheoperationisstarted.
Whenitissetto“AUTO”,theactuatorisreturnedtothehomepositionautomaticallyaftertheservo-motor
ON is input.
The above are effective only when the actuator is incremental type (for the absolute type, the home return
operationisnotrequired).
Note
7KH6HUYRPRWRU21VLJQDOLVLQSXWIRUWKH¿UVWWLPHDIWHUWKHSRZHULQSXWLQSXWWKHPRYHPHQWFRPPDQG
afterthedelaytimeof1.6secormore.
Inthesecondtimeorlater,makethedelaytimeof60msormore.
Note
3. WhentheServo-motorControlissetto“Enable”intheinitialsetting,theservo-motoristurnedONby
meansofinputtingtheSONsignal.
Whenitissetto“Disable”theservo-motoristurnedONautomatically.
Warning: For ASEP and PSEP
The magnetic pole phase detection may not be performed normally if the servo is turned on near
the mechanical end, and may cause such problems like an abnormal operation, magnetic pole not
EHLQJGH¿QHGRUHOHFWURPDJQHWLFGHWHFWLRQHUURU
Put it away from the mechanical end when turning the servo on.
Safety Circuit Status
I/O Power 24V DC Supply
Controller Power 24V DC Supply
Servo-on Input
Note 3
(SON)
LED for STATUS Indication
(Backward Position) Movement Signal (1,2) Input
(ST0)
Home Return Completion Output
(HEND)
Backward Position Detection Output
(LS0)
Backward Positioning Completion Output
(PE0)
Actuator Operation
Mechanical
end
Home
Position
6ms or less
1.6sec or less
Note 2
Note 1
Home return
Forward Position
(Single Solenoid System)
Backward Position
(Double Solenoid System)