3. Operation
No Name Initial Value Setting Range Remarks
19
Absolute Battery Retention
Time
2 0 to 3
Set the standard for the absolute data storage time.
Parameter
No.19 Setting
Encoder Max. Rotation
Speed [rpm]
Reference
for Battery
Retention
Time
(reference)
[day]
When the
connected
actuator is a
model other
than
RCA2-***N;
When the
connected
actuator is
RCA2-***N;
0 100 75 20
1 200 150 15
2 400 300 10
3 800 600 5
20
Position Data Change Password
0000 0000 to 9999 When “0000” is set, the password input is not required.
(Note 1) Please refer to the next section if the servo-motor gain adjustment is required.