Iai-america PCON-CF Manual de usuario Pagina 122

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 226
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 121
104
7. Operation <Practical Steps>
Position table (Field(s) within thick line must be entered.)
No.
Position
[mm]
Speed
[mm/s]
Acceleration
[G]
Deceleration
[G]
Push
[%]
Positioning
band [mm]
0 * * * * * *
1 150.00 200.00 0.30 0.30
0
10.00
2 200.00 100.00 0.30 0.30
0
0.10
:
T1: 6 msec or more; time after selecting/entering a command position until the start input turns ON
(The scan time of the host controller must be considered.)
Caution: When the start signal turns ON, the position complete output will turn OFF and the moving
output will turn ON.
Always turn OFF the start signal after confirming that the start signal is currently ON and the
position complete output has turned OFF.
Speed
Position 1 Position 2
Position 1
T
1
T
1
Position 2
Note
Note
Command position
Start
Position complete
Completed position
Moving
Actuator movement
Vista de pagina 121
1 2 ... 117 118 119 120 121 122 123 124 125 126 127 ... 225 226

Comentarios a estos manuales

Sin comentarios