7. Operation <Practical Steps>
T1: 6 msec or more; time after selecting/entering a command position until the start input turns ON
(The scan time of the host controller must be considered.)
Caution: When the start signal turns ON, the position complete output will turn OFF and the moving
output will turn ON.
Always turn OFF the start signal after confirming that the start signal is currently ON and the
position complete output has turned OFF.
Example of other zone output)
Zone output at 120 or more Zone output at 40 or less
Zone boundary+ Maximum stroke length Zone boundary+ 40
Zone boundary– 120 Zone boundary– 0
Zone
Zone
120
40
T
1
Command position
Start
Position complete
Completed position
Zone
Moving
Actuator movement
Speed
Note
0 mm 40 mm 120 mm 150 mm