2. ACON-C/CG, PCON-C/CG
14
2.3 Interface Specifications
Item Specification
DeviceNet 2.0
Group 2 only server
Communication protocol
Network-powered isolation node
Bit strobe Communication specification Master-slave connection
Polling
Baud rate Automatically set to the same value as the band rate set in the master
Baud rate Maximum network length Maximum branch
line length
Total branch
line length
500 kbps 100 m 39 m
250 kbps 250 m 78 m
125 kbps 500 m
6 m
156 m
Communication cable length
Note) When a large-size DeviceNet cable is used.
Communication power supply 24 VDC (supplied from DeviceNet)
Consumption current of
communication power supply
60 mA
Number of occupied nodes 1 node
Connector MSTBA2.5/5-G-5.08AU M (*1) by Phoenix Contact
(*1) The cable-end connector is a standard accessory.
SMSTB2.5/5-ST-5.08AU by Phoenix Contact