[1] Connect the controller by directly screwing it onto a metal frame.
Protective grounding
(AC power supply)
100/200-V
controller
24-V
controller
Use a cable of
a maximum
possible size
and keep the
wiring distance
at a minimum.
[2] If the controller cannot
be screwed onto the
frame, connect it to the
frame as shown in the
figure at left.
(24 VDC)
[2] 24-VDC controller
The power terminal block does not have a protective grounding terminal, but the user must separately
provide a noise elimination measure and grounding.
(2) Grounding for noise elimination
Regardless of whether the power supply is 100/200 VAC or 24 VDC, the controller must always be
grounded to eliminate noise.
[3] Precautions regarding wiring method
Use a twisted cable for connection to the 24-VDC external power supply.
Separate the controller cables from high-power lines such as a cable connecting to a power circuit. (Do
not bundle together the controller cables with high-power lines or place them in the same cable duct.)
When extending the supplied motor cable or encoder cable, consult IAI’s Technical Support.