54
(7) Acceleration only MAX
(ACC MAX)
Select the specified acceleration or maximum acceleration by entering
“0” or “1.”
The default value is “0.”
0: Specified acceleration --- The value entered in (4) becomes the
actual acceleration/deceleration.
1: Maximum acceleration --- The maximum acceleration set according
to the load is used.
The deceleration conforms to the value
entered in (4).
(7) Acceleration only MAX = 0 (7) Acceleration only MAX = 1
Note: As a rough guide, enable the acceleration only MAX setting when the actual loading capacity is no
more than one-third of the rated loading capacity.
Check the rated loading capacity of your actuator by referring to the supplied specification list of
supported actuators.
Acceleration/deceleration
set in (4)
Acceleration/deceleration
set in (4)
Maximum acceleration
according to the load
Speed
Speed
Moving distance
Moving distance