2. Installation
27
2.2 Installation and Storage • Preservation Environment
[1] Installation Environment
The actuator should be installed in a location other than those specified below.
In general, the installation environment should be one in which an operator can work without
protective gear.
Also provide sufficient work space required for maintenance inspection.
Where the actuator receives radiant heat from strong heat sources such as heat treatment
furnaces
Where the ambient temperature exceeds the range of 0 to 40C
Where the temperature changes rapidly and condensation occurs
Where the relative humidity exceeds 85% RH
This actuator possesses the water durability of IP67 protection structure.
Where the actuator receives direct sunlight
Where the actuator is exposed to corrosive or combustible gases
Where the ambient air contains a large amount of powder dust, salt or iron (at level
exceeding what is normally expected in an assembly plant)
Where the actuator receives impact or vibration
If the actuator is used in any of the following locations, provide sufficient shielding measures:
Where noise generates due to static electricity, etc.
Where the actuator is subject to a strong electric or magnetic field
Where the actuator is subject to ultraviolet ray or radiation
[2] Storage • Preservation Environment
The storage and preservation environment should comply with the same standards as
those for the installation environment. In particular, when the machine is to be stored for a
long time, pay close attention to environmental conditions so that no dew condensation
forms.
Unless specially specified, moisture absorbency protection is not included in the package
when the machine is delivered. In the case that the machine is to be stored and preserved
in an environment where dew condensation is anticipated, take the condensation
preventive measures from outside of the entire package, or directly after opening the
package.
For storage and preservation temperature, the machine withstands temperatures up to
60C for a short time, but in the case of the storage and preservation period of 1 month or
more, control the temperature to 50C or less.
Storage and preservation should be performed in the horizontal condition. In the case it is
stored in the packaged condition, follow the posture instruction if any displayed on the
package.