3. ACON-C/CG, PCON-C/CG
CC-Link
66
(30) Stop Mode Selection (ASO1, ASO0)
Select the stop mode for the duration before the movement to the next position after a positioning is
completed.
If the duration for a stop is long, the system automatically turns the servo OFF to reduce the power
consumption.
Refer to the instruction manual for the controller for more information.
ASO1 ASO0 Function Reference
OFF OFF
Disabled Set in delivery
OFF ON
Automatic Servo OFF Method
Parameter No. 36 is valid for T
ON OFF
Automatic Servo OFF Method
Parameter No. 37 is valid for T
ON ON
Automatic Servo OFF Method
Parameter No. 38 is valid for T
PLC Output Signal
T
Movement
Command
A
ctuator
Moving
Servo
Condition
Servo ON
Condition
T : Waiting time (sec) before servo is
turned OFF after the positioning is completed
Target Position
In automatic servo OFF duration
(Green LED blinks)